MedTach
Integrated Solutions for Measuring Human Physiology in Canada
  • Home
  • Solutions
    • Hemodynamics
    • Vascular Function
    • Cerebral Blood Flow
    • Cardiac Electrophysiology
    • Autonomic Function
  • Technologies
    • Finapres Continuous Blood Pressure >
      • Hypertension Information
      • Finapres Nova - Products
      • Finapres Nova - Hardware >
        • Finapres Nova - Basic
        • Finapres Nova - ECG + RESP
        • Finapres Nova - Full Option
      • Finapres Nova - Software >
        • Guided Autonomic Testing (GAT)
        • Advanced Hemodynamics
        • Autonomic Testing
      • Finapres Nova - Application Fields >
        • Autonomic Failure Diagnosis >
          • Autonomic Failure Diagnosis
        • Hemodynamic Evaluation
        • Education with Finapres
        • Other Finapres Applications
      • Technologies - Finapres >
        • Volume-Clamp: Continuous BP Method
        • Nano Core Technology - Finapres
        • Height Correction Unit - Finapres
        • Physiocal Signal Quality Indicator - Finapres
        • Compare all Finapres Products
    • Delica Transcranial Doppler
    • Caretaker Wireless ICU Grade Vital Signs >
      • VitalStream
      • Caretaker News
      • Virtual Hospital Monitoring
      • Caretaker How To Use
    • TempTraq Real-Time Fever Detection Patch
    • Bittium Faros ECG Cardiac Holter >
      • Faros Waterproof ECG
      • Cardiac Navigator Holter Analysis
      • HolterPlus Remote Cardiac Monitoring
      • Cardioscope Autonomic Testing
    • Schiller ABPM and Cardiac Holter >
      • Schiller BR-102 plus PWA
      • Schiller BR-102 plus
      • Schiller medilogAR ECG Holter
      • Schiller Cardiovit FT1
    • Kinesis Mobility & Fall Probability >
      • QTUG
      • Gait
      • Balance
    • Carrot C-Com Wireless Headset >
      • C-Com Wireless Headset
      • C-Suite
    • FIAB Transesophageal Cardiac Pacing >
      • FIAB Eso Temp Monitor
      • FIAB Eso Leads
  • Support
    • Telemedicine
    • Finapres FAQ
    • Bittium Support
    • Kinesis Setup & FAQ
  • Contact
    • Who We Are
Picture

Finapres NOVA

Continuous, Beat-to-Beat Blood Pressure and Advanced Hemodynamics — Without Invasive Lines

Finapres NOVA captures arterial pressure on a beat-to-beat basis, enabling real-time insight into cardiovascular regulation.
Rather than relying on intermittent measurements, it reveals how blood pressure, cardiac output, and vascular dynamics change moment-to-moment — making it a powerful tool for both controlled research and applied clinical environments.
Request Information
Speak with a Specialist

What The Finapres NOVA Enables

Capture Beat-to-Beat Blood Pressure Changes

Measure arterial pressure continuously, revealing dynamic changes not visible with intermittent methods.

Understand Cardiac Output and Hemodynamics

Derive stroke volume, cardiac output, and vascular resistance from the pressure waveform.

Assess Autonomic Cardiovascular Function

Quantify baroreflex sensitivity and heart rate variability to study nervous system regulation.

Measure Real-Time Physiological Response

Track cardiovascular responses during posture changes, interventions, and stress conditions.

How Finapres Works

Finapres uses a finger cuff and validated modelling techniques to continuously measure arterial pressure and derive cardiovascular parameters in real time.​

A Dynamic Finger Cuff

The system maintains constant blood volume in the finger artery by continuously adjusting cuff pressure. This allows arterial pressure to be tracked non-invasively with high fidelity.

Beat-to-Beat Waveform Capture

Each heartbeat is recorded as a full pressure waveform, revealing subtle changes in cardiovascular dynamics that are lost with intermittent measurements.

Model-Based Hemodynamic Analysis

Using validated physiological models, the system translates the pressure waveform into meaningful parameters such as cardiac output, stroke volume, and vascular resistance.
Contact Us

Key Capabilities

Finapres NOVA combines continuous blood pressure measurement with advanced modelling and analysis to provide a comprehensive view of cardiovascular function.

Beat-to-Beat Cardiovascular Monitoring

Continuous blood pressure and cardiovascular dynamics

Trusted Model-Based Hemodynamic Parameters

Calculation of cardiac output, stroke volume, and vascular resistance using validated modeling approaches ​

Baroreflex Sensitivity (BRS)

Quantification of cardiovascular reflex control and blood pressure regulation ​

Heart Rate Variability (HRV)​

Time- and frequency-domain analysis of autonomic nervous system activity ​

Real-time waveform analysis and export 

​

Modular System Design

Expandable with ECG, SpO₂, Guided Autonomic Testing (GAT) protocols, and additional software applications to support a wide range of study designs. Build what you need.
Contact Us

System Configuration

Finapres NOVA is designed as a modular platform, allowing systems to be configured based on specific research or clinical requirements.
Build a system that matches your study — from core monitoring to fully integrated physiological setups.

Core System

  • Continuous non-invasive blood pressure (finger cuff-based) 

Optional Modules

ECG (for HRV and autonomic analysis)
SpO2
Upper Arm Calibration
Analogue input/output integration
GAT additional hardware

Software Applications​

Advanced Hemodynamics
Autonomic Testing
Guided Autonomic Testing
Picture of all outputs wiht different builds
Applications
Finapres NOVA is used in environments where understanding cardiovascular dynamics — not just measuring them — is critical.
In cardiovascular physiology research, it enables detailed analysis of cardiac output, vascular resistance, and blood pressure regulation.
In autonomic testing, it provides the resolution needed to quantify baroreflex function and nervous system control during protocols such as tilt and active stand.
In applied and clinical research, it captures real-time responses to exercise, stress, and interventions — helping bridge controlled studies with real-world physiology.

Cardiovascular physiology research​

Study cardiac output, vascular resistance, and blood pressure regulation

Autonomic Function Testing

Assess cardiovascular control using tilt table and active stand protocols

Exercise and stress testing

Measure real-time cardiovascular responses to physical and physiological stress

Clinical and translational research

Bridge laboratory findings with real-world physiological outcomes

Pharmacological and intervention studies​

​Evaluate cardiovascular responses to therapies and interventions
View All Technologies

What Makes Finapres Different

Built on decades of validated research and clinical use in non-invasive hemodynamic monitoring 
  • Captures continuous, beat-to-beat dynamics instead of static snapshots
  • Reveals physiological changes that intermittent systems miss
  • Combines hemodynamic and autonomic analysis in a single platform
  • Built on validated models and decades of cardiovascular research
  • Flexible across controlled lab and applied environments

How MedTach Supports You

Accurate physiological data depends not just on the system, but on how it is configured and used.

We work with your team to ensure Finapres is aligned with your study design, properly implemented, and delivering reliable data from the start.
​
From onboarding and training to ongoing support, we help maintain consistency across studies, users, and evolving research needs.

Build a Complete Measurement Setup

Finapres is often used alongside complementary systems to provide a more complete view of cardiovascular and physiological function.
Explore how it integrates with vascular function assessment, cardiac electrophysiology, and broader physiological monitoring solutions.

Considering Finapres NOVA for your research or clinical application?

We’ll help you determine the right configuration and approach for your study.
Discuss Your Study
MedTach Inc.
Head Office
​4145 North Service Rd., Suite 200
Burlington, Ontario, Canada L7L 6A3
1-289-644-4985 |
[email protected]


Copyright © 2026 MedTach. ​All Rights Reserved.
Contact Us